VELOX monolithic ceilings are key elements of ribs formed using PERI slab elements.
• Ceiling element's basic dimensions: length l = 2000 mm, width 500 mm = b1, b2 = 380 mm
• Module dimensions: length 1830, 1660, 1500, 1330, 1000, 660, 500, 330 mm, width 330 mm = b1, b2 = 180 mm
• Choice of its application depends on the range, payload, ceiling object quality concrete and reinforcement content
• Reinforcement ribs are ceiling VELOX spatial steel beams, respectively.
• Coupled Reinforcement every two meters, i.e. at the connection of ceiling elements for greater spatial bracing object transverse ribs
• Deployment supports - under the front contact elements

Ceilings created with monolithic reinforced concrete ceiling cassette (non-standard elements)
• Used for ceilings with 'special use' (concert halls, theaters, etc.)
• Transverse ribs are positioned in axial distances of 500, 660, 1000, 1330, 1500, 1660, 1830, 2000 mm
• Choice of application depends on the range, payload ceiling of the building, the quality of the concrete and reinforcement content
• Reinforcing ribs bonded reinforcement supports deployment by the length of the ceiling element
• Used for ceilings with 'special use' (concert halls, theaters, etc.)
• Transverse ribs are positioned in axial distances of 500, 660, 1000, 1330, 1500, 1660, 1830, 2000 mm
• Choice of application depends on the range, payload ceiling of the building, the quality of the concrete and reinforcement content
• Reinforcing ribs bonded reinforcement supports deployment by the length of the ceiling element

Height fittings + concrete slab (mm) | Ceiling Height (mm) | Standard computational load limits (kN / m 2 ) | Max. bright range (m) |
170 + 50 | 220 | 6.99 | 5.9 |
220 + 50 | 270 | 7.36 | 6.9 |
260 + 50 | 310 | 7.65 | 7.7 |
315 + 50 | 365 | 8.04 | 8.6 * |
350 + 50 | 400 | 8.32 | 9.6 * |
400 + 50 | 450 | 8.69 | 10.2 * |
500 + 50 | 550 | 9.48 | 11.2 * |
575 + 50 | 625 | 10.09 | 12.0 * |